40 CFR Part 82 Subpart F · 40 CFR Part 84 Scope

EPA Section 608 Practice Test & 40 CFR Diagnostic

Practice with 55 original questions written directly from U.S. Federal Regulations. Every item includes its exact 40 CFR citation, effective-rule scope, and distractor analysis—scored strictly against the 70% (18/25) Core-gate rule locally in your browser.

25 Core · 10 Type I · 10 Type II · 10 Type III 70% (18/25) Closed-Book Benchmark · Not an Official EPA Exam
Core (25) · Question 1 of 25 · 0 answered Local Browser Only · No Uploads
CORE-01 Core Venting Prohibition

Enable JavaScript to load the interactive 55-question EPA Section 608 diagnostic, or review the official 40 CFR scoring rules and Study Guide tables below.

Official EPA Section 608 Exam Structure & Passing Rules

Under 40 CFR §82.161, EPA-approved certifying organizations (such as ESCO Group, SkillCat, Mainstream Engineering, and Ferris State) administer official proctored certification exams under their published session procedures. Verify current rules directly at epa.gov/section608.

Certification Path Required Sections Official Closed-Book Benchmark Primary Regulatory Scope
Core (Mandatory Foundation) Core only (no standalone card) 18 / 25 (72%, >= 70% rule) 40 CFR §§82.150–82.166, 49 CFR Cylinders, ASHRAE 34
Type I (Small Appliances ≤ 5 lbs) Core + Type I 18 / 25 each (84% if mail-in open-book Type I) 40 CFR §82.152, §82.156(b), §82.158(d)
Type II (High-Pressure Appliances) Core + Type II 18 / 25 each (closed-book) 40 CFR §82.156 Table 1, §82.157, 40 CFR §84.106
Type III (Low-Pressure Chillers) Core + Type III 18 / 25 each (closed-book) 40 CFR §82.152, §82.156 Table 1, §82.158
Universal Core + Type I + Type II + Type III 18 / 25 on all 4 sections All appliances covered under 40 CFR Part 82 Subpart F

Need the Evacuation & Leak-Rate Tables Side by Side?

Open the dedicated 40 CFR Study Guide for the complete §82.156 Table 1 vacuum thresholds, Part 82 vs. Part 84 leak-repair comparison, Type III chiller sequence, keyword lookup drill, and a 2-page printable PDF cheat sheet.

Open 40 CFR Study Guide

Frequently Asked Questions

Is CFRTestPrep an official EPA Section 608 exam?

No. CFRTestPrep is an independent practice diagnostic and 40 CFR study reference. Official certification cards are earned only through EPA-approved testing organizations—such as ESCO Group, SkillCat, Mainstream Engineering, or Ferris State—under their proctored exam rules.

What score is required to pass an official closed-book EPA 608 exam?

Official closed-book Section 608 exams contain 25 questions per section and require at least 70% (18 out of 25) to pass each section. You must pass Core alongside Type I, Type II, or Type III (and all four at 18/25 or higher for Universal). Mail-in open-book Type I exams (where offered) require 84%.

Why does this diagnostic fail you if Core is below 70% even with a high total score?

Under 40 CFR §82.161 and EPA testing rules, sections are graded independently and passing Core is mandatory for every certification path. Scoring 100% on Type II does not compensate for a failing Core score.

Why do the Type II questions separate 40 CFR §82.157 from 40 CFR §84.106?

40 CFR §82.157 governs leak inspection and repair for appliances containing 50 pounds or more of ozone-depleting refrigerants (ODS). Under the AIM Act, 40 CFR §84.106 extends 30% / 20% / 10% leak repair thresholds to covered HFC and substitute appliances (>53 GWP) holding 15 pounds or more starting January 1, 2026—while §84.106(a)(3)(ii) explicitly exempts appliances in the residential and light commercial air conditioning and heat pump subsector.

Are my test answers or generated Cram PDFs uploaded anywhere?